Details
The Hanna Phosphate Ultra Low Range (0.00 to 0.90 ppm) Checker® bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits have limited accuracy and resolution since they rely upon the human eye to discern differences in color. Professional instrumentation incorporates a light source such as an LED or tungsten lamp with a filter and a light-sensing detector to precisely determine ion concentration. Professional instrumentation offers greater resolution and accuracy but can cost hundreds of dollars. The Hanna Phosphate Ultra Low-Range Checker® uses a fixed wavelength LED and silicon photo detector to provide the accuracy of professional instrumentation at the affordable price of a chemical test kit.
Features
- Compact, Portable Design
- Built-in Timer
- One-Button Operation
More Information
The HI774 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure phosphate in marine systems including coral reef tanks. Phosphate is an important parameter to measure in aquaculture and aquariums; levels that are too high can lead to extensive algae growth, depleted dissolved oxygen levels, and ultimately can be fatal to many types of fish and aquatic life. Designed as a more accurate alternative to chemical test kits, the HI774 provides quick, accurate results. For those that would like measure phosphate as phosphorous we off the HI736 Phosphorous Checker® HC. Alternatively, to determine the fraction of phosphorous (PO4-P) there is in phosphate (PO43-) the phosphate reading is multiplied by 0.3261. A 0.50 ppm phosphate reading is equal to 0.163 ppm or 163 ppb phosphorous.
Marine Phosphate Ultra Low Range Checker - HI774
Phosphate Range 0.00 to 0.90 ppm Phosphate Resolution 0.01 ppm Phosphate Accuracy +/- 0.02 ppm +/- 5% of reading Phosphate Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic-Acid method. The reaction between phosphate and the reagent causes a blue tint in the sample. Photometer/Colorimeter Light Source LED @ 525 nm Photometer/Colorimeter Light Detector silicon photocell Battery Type/Life (1) 1.5V AAA Automatic Shut-Off after seven minutes of non-use and two minutes after taking a reading Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Weight 64 g (2.25 oz.) Dimensions 86.0mm x 61mm x 37.5mm (3.4" x 2.4" x 1.5”) Ordering Information HI774 Checker® is supplied with (2) sample cuvettes with caps, phosphate ULR reagent for 10 tests, battery, instructions and quick start guide.